Commercial Windows
PTAC-Integrated Windows
A window assembly coordinated with a packaged terminal opening in the same wall area.
PTAC-integrated windows are requested when the architectural opening and the mechanical sleeve share a wall. The window quote has to follow the sleeve width and height on the mechanical drawings. Division 8 USA does not publish a standard sleeve size on this site.
Send the PTAC manufacturer and model only if they are already on the schedule. Do not assume a sleeve dimension from a unit type.
Where it is specified
- Hotel and multifamily rooms with a through-wall terminal
- Senior living rooms with a packaged terminal unit
- Renovations replacing both the sleeve and the adjacent glass
Reference specification
Figures published for this window.
Use these numbers as a quoting reference. The project specification controls if it asks for a different approval, glass, or performance value.
| Item | Published figure |
|---|---|
| Opening styles named | Sliding and casement |
| Thermal insulation | U ≤ 0.5 W/m²·K |
| Acoustic performance | ≤ 45 dB |
| Air tightness | ≤ 0.4 m³/(m²·h) |
| Wind load resistance | ≥ 2.8 kPa |
| Water penetration | ≥ 450 Pa |
| Standards named on the product page | FPA, NOA, AS2047, NFRC, CSA |
| Factory warranty stated | 10 years |
| Applications named | Apartment and hotel |
| Construction described | Thermal-broken aluminum frame built around a PTAC louver and factory-mulled to the adjacent window, installed in one rough opening |
Configurations that can be requested
- Single window panel with a louver
- Double window panel with a louver
- Louver sized to the PTAC sleeve on the mechanical schedule
- Glass beside, above, or factory-mulled around the sleeve, as the elevation shows
Frame finishes, glass makeups, screens, grilles, and hardware lines are listed on the commercial windows page.
Confirm before pricing
- These figures are manufacturer-published reference values. They are not a Division 8 USA test report, warranty, or product approval.
- No standard sleeve width or height is published here. Send the sleeve size from the mechanical drawings.
- U ≤ 0.5 is published in watts per square meter kelvin. An NFRC U-factor in Btu/h·ft²·°F was not published, and this site does not convert the number.
- A repeated construction list on the source pages mentions a tilt-turn AAMA CW-PG60 rating. That line is not treated as a PTAC-specific rating because the same paragraph is pasted onto other window types.
Quote
What to send for this product.
Pricing is prepared for the project. There is no public list price.
- Sleeve width and height from the mechanical drawings
- Whether the glass is beside, above, or around the sleeve
- Opening type and rough opening or unit size
- Frame finish
- Glazing, if the specification requires it
- Quantity and project location
- Specification section
Questions
Before you price this item.
What does PTAC-integrated mean here?
The window opening is priced together with the packaged terminal sleeve shown on the drawings.
Do you choose the PTAC unit?
No. Send the mechanical schedule. The window request is coordinated to that opening.
Are the performance numbers on this page a Division 8 USA test report?
No. They are manufacturer-published reference figures. The quote follows the specification section and the mechanical sleeve size.
Related